Chemstation Calibration

Chemstation Calibration

The ChemStation integrator can satisfactorily integrate all types of chromatograms, including those with difficult baselines and negative peaks. You can control the integration process by setting. Yes, you would follow the same process but stop after adding the first level. As long as the origin is included in the calibration curve then the software will draw a line between the origin and the single calibration point to generate the curve.

Chemstation Calibration

I am working with Agilent Chemstation and am trying to analyze for 3 compounds. I have created an 8 point calibration curve and have a good linear regression for each compound. My calibration curve ranges from 0.05 ug/ml to 10.0 ug/ml. When I go to reprocess my calibration curve for 0.05 and 1.0 ug/ml I receive amounts such as 0.00 for the first compound, 2.3e-3 for the second and 3.4e-1 for the third compound at standard 0.05 and for 1.0 ug/ml I receive 1.1e-3 for the first compound 2.4e-2 for the second and 3.4e-1. At first I thought maybe I should recalibrate or make a new curve but when I do the first two cal points (0.05 and 1.0) and then go back to the first cal-point 0.05 I get the results (5.5e-2 5.4e-2) that I am looking for. Another frustraiting issue is that samples that are in the middle of my cal-range (1.0 ug/ml) come as expected. Also when I go to calculate other samples at 0.10 concentration the area is the same as my standard in the calibration curve (44.372) but the concentration amounts are not the same. Any clues as to how I might be able to fix this?

Chemstation Calibration Curve

A calibration curve is an empirical equation that relates the response of a specific instrument to the concentration of a specific analyte in a specific sample matrix (the chemical background of the sample). As with the instrument response function, the calibration curve can have a number of mathematical forms. ChemStation’s partnership is part of the Safer Choice initiative for commercial formulation with the basic goal of the initiative to seek and promote innovative chemical products, technologies, and practices that benefit human health and the environment. A key purpose of the partnership program is to recognize and encourage the formulation of. A Production Management And Recall Tracking Solution. ChemStation Collaboration.